With DPA5 adapter,I try to connect with Cummins insite and i have error code 5204 or only no connection and not blinking the leds
This is the error 5204 popped up when connect Prostar 2005 with cummins engine:
ECM connection
Error number: 5204
Communication between the data link adapter and the ECM could not be established.
Please check the following conditions:
The key switch is on
The cables are between the data link and the ECM are properly connected
The cables are in good condition
The correct adapter type is selected
The correct communication protocol is selected
Select retry, cancel or help for additional troubleshooting steps
Here is what have been tried but failed!
Try to connect whit J1939…..same issue
On truck does not even get the engine and the others only couple line and very slow, might be some thing with them trucks
Some things odd2006 models connect through J1939 and works.
Tried on 3 trucks already that are 2005 and older the connect thought J1708 it says engine 128
And when doing the J 1939 test on them it says something like data error
Check the driver is installed well
J1939 & J1708 are added to the software
Finally, SOLVED!
The solution is this, connect, then scan to diagnostic connector but not to USB, open the Cummins insite and push connect, when the Insite begin to connect, immediately connect the USB and ready….
The final tip- Error Messages for communication failures:
Error 5200: Indicates communication loss between computer and the data link adapter.
Error 5201: Indicates communication loss between the data link adapter and the ECM.
Error 5202: Indicates no communication could be established between the Data link adapter and the computer.
Error 5204: Indicates no communication could be established between the Data link adapter and the ECM.
If the “Auto Configure” and/or “Data link Adapter Connection Test” do not find the adapter when connected, manually configure the Cummins INSITE 6 Data link adapter connection.