Yesterday one of obd2tool.co.uk customer from Netherlands ask us : How can I Offline SCN Coding By MB SD C4 And DAS? Obd2tool.co.uk engineer give him a detail instructions, let’s see together :
Requirement for offline SCN coding:
–STAR DIAGNOSIS (MB SD CONNECT COMPACT 4 is the most reputable in the market now) diagnosis system with printer
–Fax
This is the detailed instructions to display offline SCN coding via Star diagnostic software Diagnosis Assistance System (DAS).
Steps for offline SCN coding:
A) Determine vehicle data for offline SCN coding from the vehicle.
1 Select control unit in DAS.
2 Select menu item “control unit adaptations” or “initial startup”.
Continue with “F3″.
3 Select menu item “SCN coding”. Continue with “F3″.
4 Select “Offline (STAR DIAGNOSIS device not-networked)” menu item. Continue with “F3″.
5 Confirm note on sequence of SCN coding with “F2″.
6 Completely fill out fax form and click “F11″ to print out.
Please Kindly Notice:If an email address is entered in the fax form, you will be sent the SCN coding data per email. If a fax number is entered in the fax form, you will be sent the SCN coding data per fax.
7 Send printed out fax form to the given fax no. for the Star Diagnosis Help Desk.
B) Perform SCN coding. The coding is performed with the SCN coding data from the Star Diagnosis Help Desk.
Please Kindly Notice: If the SCN coding data are received per email, burn the data to a CD or save the data on a USB removable storage device and identify accordingly. Unpack the Zip files first when doing so.
8 In the DAS, choose the “Step 2: Perform SCN coding” menu item. Continue with “F3″.
9.1 Select keyboard input using “F4″.
For SCN coding data per fax.
9.2 Insert CD or connect USB removable storage device.
For SCN coding data per email.
10.1 Enter SCN coding data manually into the DAS.
For SCN coding data per fax.
10.2 Confirm using “F3″ and import the data per CD or USB removable storage device.
For SCN coding data per email.
11 Perform SCN coding.
12 Switch ignition on/off.
Control unit specific, refer to specification in DAS.
13 Press “F11″ to print out the order log and enclose the repair order.
Please Kindly Notice: The order log can also be stored on the DAS. This is done by clicking on “F11″, “Print to file”, selecting “printout of test step” and entering a file name. In StarUtilities, the StarPad program can be used to display and printout the order log at the “Logs” menu item.
14 Continue with “F2″.
Please Kindly Notice: The SCN coding of the control unit is completed. Scrap the CD following successful SCN coding as per the guidelines for theft-relevant parts (DTR 69/00). The scrapping process is to be documented on the repair order. The data on the USB removable storage device are to be deleted properly once they have been used.
PS. Here, we highly recommend you to buy the plug-and-play star diagnostic bundle (SD C4 with laptop)for your programming to in case of unnecessary inconvenience, such as installation problem.
Version 2012.11 star diagnosis is good at offline programming.
Hope it would help you.